● Implementation of water treatment by dissolved air flotation
Separation of suspended particles
Agglomeration by using air bubbles dissolved
Optimization of the process
Combination with chemical treatment (flocculation)
Feasibility study on different waters
Study of the influence to flow rate and residence time
General specifications
• 100 L feeding tank.
• Centrifugal pump
• 40 L, flocculation tank, with stirrer.
• 100 L, flotation tank.
• Two recirculation pumps.
• Gas‐ liquid contactor.
• Water feeding circuit.
• Compressed air circuit.
• Air‐to‐water feeding circuit.
Instrumentation
• Water flowmeter.
• Water flowmeter.
• Air flowmeter.
• 4 manometers.
This unit allows the user to perform a water treatment by flotation tanks to dissolved air developed. It is carried out in 4 steps:
‐ Bubbles generated for dissolved air.
‐ Bubble adhesion to particles in order to form solid‐air particles.
‐ Formation of an air/solid particle conglomerate and flota
‐ tion of the formed conglomerate. ‐SeparaƟtin of the floaƟtig emulsion.
2 boosters pumps allows the pressurization in the liquid air contactor and generate dissolved air in water.