C492/230/A/B COMBUSTION LABORATORY UNIT - GAS and OIL BURNER SUPPLIED

产品时间:2022-03-03 09:27:52

简要描述:

Features Purpose built Insulated Combustion Chamber, with Instrumentation. Designed for Supervised Student Operation. Flame Failure Device. Comes Pre-fitted Fitted with Gas Burner (for use with LPG/Me

详细介绍

Features 

Purpose built Insulated Combustion Chamber, with Instrumentation. 

Designed for Supervised Student Operation. 

Flame Failure Device. 

Comes Pre-fitted Fitted with Gas Burner (for use with LPG/Methane) 

Supplied with Oil burner and 2 different fuel tanks. 

Changes to Burner Settings Quickly and Easily Observed. 

Fuel and air adjustment available. 

Variable water jacket temperature allows domestic heating simulation 

Flue gas and AFR analysis available as standard. 

Flame and flue Temperature measurement. 

Research possibility to test new (liquid) fuels within range of burner specifications. 

Optional Computerised Data Acquisition Upgrade.

Description 

The Hilton Combustion Laboratory Unit enables students to study many aspects of combustion and Burner operation using burners typical of those used commercially. A Gas burner is fitted as standard, and a Oil burner is supplied with the unit also. The unit is frame mounted, is fully instrumented and requires only a conventional single phase electrical supply, cooling water and the chosen fuel. As a purpose built training unit it is designed for supervised student operation by including several safety features. A hand held digital gas analyser supplied allows the O2 content of the flue gas to be determined and this in turn allows calculation of the air /fuel ratio, excess air and combustion efficiency. For advanced students or research, an optional high specification gas analyser C492D is available that allows investigation of CO, NO and SO2 in addition to the standard analysis. The unit will be of wide interest to all those concerned with the combustion of fuels and energy conservation, from the burner maintenance technician, to research and test engineers.

Related Laws/Applications 

Building services 

Mechanical Engineering 

Marine engineering 

Chemical engineering 

Mining engineering 

Environmental engineering 

Energy Conservation 

Industrial Research 

Vocational, Plant Maintenance 

Fuel Technology 

Thermodynamics

Learning capabilities 

Familiarisation of the adjustment and operation of a commercial Gas and Oil burner. 

Assessment of a burner 

Firing rate 

Turndown range 

Flame stability 

Flame shape 

Flame radiation 

Smoke emission 

Using either clean light boiler fuels, or natural gas or LPG 

The effect of air/fuel ratio on Combustion efficiency as measured by flue gas constituents and temperature. 

The effect of air/fuel ratio on Heat transfer 

The effect of air/fuel ratio on Energy balance 

Comparison of Flue Gas Analysis with theoretical predictions. 

Comparison of Oil and Gas Burners (With optional extra Burner) 

Comparative performance of different fuels or fuel additives.

Technical Specification 

Frame: Powder coated 25 mm mild steel angle frame with 16 swg shelves. 

Chamber: Stainless steel combustion chamber, approximately Ø450 mm ID, Ø500mm OD x 1000 mm long, with four 100 mm quartz glass windows. 

Chamber and end plate water cooled, front plate has 80mm thick insulation and burner mounting studs. 

Gas Burner: Package burner with integral fan and control box, and multibloc valve. Operates on natural gas (methane) or LPG gases at heat rates up to 100kW approx. (depending on fuel). 

Oil Burner: Package burner with integral fan and control box. Pressure jet atomisation. Two interchangeable nozzles of 1.5 and 2.2 US gall/hr (5.1 & 7.57 L/hour) working at 8 to 15 Bar (116 to 200 psi) with 60° spray angle, giving heat rates up to 108kW approx. (depending on fuel). 

NOTE MAXIMUM PRESSURE ON KEROSENE is 10 Bar

Recommended Ancillaries 

C492C 

C492D 

What’s in the Box? 

1 x C492 (Gas Burner fitted) 

1 x Oil Burner (not fitted) 

1 x Water Cooled probe 

1 x CO2 Detector 

Smoke Test kit 

1 x Tool kit 

Fuel tank 

Fittings 

Oil Flow Meter Display Unit 

Instruction manual 

Packing list 

Test sheet 2 year spares 

You might also like 

C492/230/A 

C492/230/B 

Weights & Dimensions 

Weight: 250 kg 

Length: 2000mm 

Width: 600mm 

Height: 1700mm 

Essential Services 

220-240 Volts, Single Phase, 50Hz(With earth/ground). 

Line current up to 3A at 230v. 

Water: Up to 25 litres m-1 at a minimum of 10m head. Open drain for this flow rate. 

Gas: LPG at maximum 2bar or mains natural gas at maximum 50mbar. Flow rate 1 to 3 g/s 

Oil: Kerosene, gas oil or other clean light fuels (density 790 - 835 kg/m3, viscosity 0.011 - 0.055 cm2/s@ 40 C). Flow rate 2 to 5 g/s. 

Extraction Suitable ducting to extract 3m3/min of exhaust gases at upwards of 400°C out of the building – C492C recommended. 

Ventilation Room must be adequately ventilated to provide 8m3/min of fresh air flow. 

Ordering information 

To order this product, please call PA Hilton quoting the following codes: 

C492/230/A/B 

C492/230/A/B/CC

 


产品咨询

留言框

  • 产品名称:

  • 留言内容:

  • 您的单位:

  • 您的姓名:

  • 联系电话:

  • 常用邮箱:

  • 详细地址:

推荐产品

Copyright © 2012-2020 北京青铄鑫业科技有限公司 版权所有  京ICP备 13039369号

地址:北京市昌平区黄平路19号院4号10层 电话:18500300266 邮箱:sale@tsingso.com